Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13604502
| No.13604502
- Product Categories
- Friendly Links
| Information Name: | Used lease sales network analyzer 8753ES |
| Published: | 2014-12-16 |
| Validity: | 30 |
| Specifications: | 3g / 6g |
| Quantity: | 3.00 |
| Price Description: | |
| Detailed Product Description: | Agilent 8753ES RF network analyzer to meet the research lab or manufacturing test requirements, in terms of speed, performance and convenience to provide an unparalleled combination confer. 8753ET and 8753ES its cover 3 or 6GHz frequency range of integrated S-parameter test set, dynamic range and frequency sweep up and 110dB power sweep for the characterization of active or passive networks, linear and nonlinear characteristics of components and subsystems provide a complete solution. Agilent 8753ES Products: * Frequency range: 30kHz-3 or 6GHz · integrated T / R or S-parameter test set up to 110dB dynamic range · · fast measurement speed and data transfer rate * plus large-screen LCD display for external monitor Used for VGA output · Display all four S-parameters HP8753ES · The instrument status and data storage / recall to the built-in floppy disk drive * optional time-domain measurements and scanning harmonic measurement. Agilent 8753ES RF network analyzer to meet the research lab or manufacturing test requirements, in terms of speed, performance and convenience to provide an unparalleled combination confer. 8753ET and 8753ES its cover 3 or 6GHz frequency range of integrated S-parameter test set, HP8753ES up the dynamic range and frequency sweep and power sweep to 110dB, HP8753ES for the characterization of active or passive network components and subsystems of linear and non- linear features provide a complete solution. HP8753ES product series features · Select the transmission / reflection analyzer (ET-type) or S-parameter analyzer (ES) allows you to target your application to select the best relationship between price and performance. · There are two independent measurement channels can simultaneously measure and display all four S-parameters. You can choose to use the amplitude, phase, group delay, Smith chart, polar, VSWR or time-domain format to display any combination of reflection and transmission parameters. · Easy to use special function keys to quickly access the various measurements, in order to take advantage of up to 4 Pin grid scale in resolution LCD color display screen with overlapping or separate form GA-compatible output. · 8753ES test function allows a sequence typing quickly and repeatedly perform complex tasks. · 8753ES in the timing of work, only one measurement from the panel, the analyzer is easy to fix IF IF test or scan mode complete conversion loss, phase, group delay and mixers tracking measurements. · Power meter calibration to absolute input or output level-sensitive devices provide absolute power leveled. · Agilent 8753ET / ES automatically 436A, 437A E4418B power meter or E44198B control, so that the power in the test system are transferred to any place with a power meter accuracy, or the network analyzer receiver calibration for accurate absolute power measurement. · Other productivity features include support for built-in floppy disk drive LIF and DOS formats, non-volatile memory, serial and parallel interfaces, DIN keyboard interface and print output and document provides a real-time clock time record, including stress testing, HP8753ES any frequency test and mark tracking, HP8753ES through the use of special frequency scanning mode to select the list to be tested and set up an independent public IF bandwidth, and power level in each frequency range, you can shorten the measurement time, segmented calibration and interpolation error correction Joe can improve the accuracy of the analyzer has a certain amount of the section on the frequency range of the school. · 8753ET / ES and 8753D / E is code-compatible, so no need to modify existing software. · HP8753ES With Option 010, reflection or transmission can be observed in the time domain response. The analyzer of the inverse fast Fourier transform to calculate frequency domain data to display the reflection coefficient or transmission coefficient versus time relationship. Two ways to observe time-domain analysis step response or impulse response of peripheral devices. In addition to the timing of the strobe can be used to respond to undesired Rebel, such as joint mismatch, gating results in the input domain may be displayed or frequencies. Combined with the time-domain analyzer function parameters HP8753ES network for advanced harmonic resonator bandpass filter provides a simple deterministic method, the response of the filter response in the time domain reflection tuned filter with the appropriate comparison, can prompt What needs to adjust or coupled resonator tuned using time domain filter tuning, it is easy for this complex task of training new personnel, and greatly simplifies the fine tuning and troubleshooting procedures. · In order to carry out more advanced device characterization, Option 002 adds harmonic measurement function. Directly or dBc relative to the fundamental wave number of the second amplifier and the display scan total harmonic level. Push a button, you can measure up to -40dBc harmonic of. · Aglient 8753ES is characterized by a magnitude and phase measurements provide a variety of built-in 50Ω or 75ΩS parameter test. HP8753ES full two-port error correction function provides a high level of accuracy, S-parameter test is easy to perform forward and reverse sweep measurement without inversion DUT. · To increase flexibility, the option to cancel the configuration of the 011 built-in test equipment, in order to select the required test equipment since Pakistan. 8753ES Option 011 can be used with a dedicated test HP85046A / B and 85047A S-parameter test set, and other special applications for devices supporting the use. ? Option 014 for maximum flexibility in Wan Lai HP8753ES provides testing device can be configured. For convenient and accurate measurement in a non-coaxial system, special offers TR * / LRM * calibration. HP8753ES removed adapter with built-in calibration technology, but also to achieve high-precision measurement of non-plug-in devices. Agilent 8753ES vector network analyzer can conduct a comprehensive evaluation of RF components. 300 kHz to 3 or 6 GHz · frequency and power sweep · adapt 50Ω and 75Ω · optional time domain harmonic measurement, you can configure the test device, remove the test device · electrical calibration (ECal) Options and Features: * 002: Harmonic wave measurements · 006: 6GHz frequency extension * 010: * 011 time-domain functions: remove the built-in test equipment * 014: configurable test device · 075: 75Ω impedance · 01D5: high stability frequency reference |
Admin>>>
You are the 5223 visitor
Copyright © GuangDong ICP No. 10089450, Letter Tianjin Communications Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5223 visitor
Copyright © GuangDong ICP No. 10089450, Letter Tianjin Communications Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

